Fire Retard Low Smoke (F.R.L.S) Cable

Fire Retard Low Smoke (F.R.L.S) Cable

CONDUCTOR:

It is manufactured from electrolytic grade bright Annealed Bare Copper which provides maximum conductivity to the flow of electricity thus, helping to save the energy.

INSULATION:

AMBY VELLY FR-LSH Cables offer two most significant and desirable characteristics of specially formulated PVC Compound i.e. very high Oxygen and Temperature Index Escalated Index values lead to optimum levels of non-combustibility. With the enhanced Dielectric strength of high Insulation Resistance, it can withstand abrupt increase of load in electric circuit of sudden voltage surges that may arise due to any irregularities in the supply system. Emission of smoke of the specially designed PVC compound is less than 50% in comparison to the ordinary PVC. Containing lesser amount of corrosive and acid fumes (HCL) of fire break out in an abnormal situation helps smoother rescue operations of precious properties and priceless Human lives.

GET QUOTE
Fire Retard Low Smoke (F.R.L.S) Cable

Rani Sati Industry’s manufactured proficiency enables AMBY VELLY Cables are capable of handling 105℃ operating temperature along with excellent Fire, Heat retardant & non-toxic characteristics. It is manufactured using min 99.97% Electrolytic grade, annealed bare copper with more than 100% conductivity. Insulated with specially formulated PVC polymer, manufactured & formulated in-house. Amby Velly ensures better reliability, energy efficiency & highest level of safety during fire.

Fire Retardant Low Smoke Halogen Free (FR-LSH) PVC insulated (unsheathed) single core multi strand cable with electrolytic grade Annealed Bare Copper conductor suitable upto 1100 v. conforming to IS:694-2010

Nominal Area of Conductor

(Sq.mm)

Number/O.D of

Each wire

(mm)

Nominal Thickness of Insulation

(mm)

Approx. Overall Diameter

(mm)

Current carrying Capacity Max. Resistance

At 20⁰ C

(Ω/Km)

In Conduit

(Amps.)

 Unenclosed

(Amps.)

0.50 16/0.2 0.6 2.2 04 05 39.00
0.75 24/0.2 0.6 2.5 07 08 26.00
1.0 14/0.3 0.7 2.8 11 12 18.10
1.5 22/0.3 0.7 3.1 13 16 12.10
2.5 36/0.3 0.8 3.8 18 22 7.41
4.0 56/0.3 0.8 4.4 24 29 4.95
6.0 84/0.3 0.8 5.0 31 37 3.30
10.0         80/0.4 1.0 6.5 46 1.91
16.0       126/0.4 1.0 7.4 62 1.21

Additional Flame Retardant Low Smoke FR-LSH properties

TEST SPECIFICATION SPECIFIED VALUES
Critical Oxygen Index IS: 10810 Minimum  29%
Temperature Index IS: 10810 Minimum  220⁰ C
Smoke Density IS: 13360 Maximum 60% (pt6/sec 9)
Acid Gas generation(Hydrochloric Acid) IS: 13360 Maximum 20%

Quotation Form

We Are Instrumental In Manufacturing A Qualitative Range Of Copper, Aluminium, Single & Multi Core Sheathed/Unsheathed Cables Including Co-Axial Cable.